# mainskeeper CLI — PROPOSED product contract, not shipped software. Fictional demonstration data.
# screen: status-bw · host: bw-pi-01 · 80 columns · NO_COLOR · exit 0
# clock: Wed 30 Sep 2026 15:22 PDT · Fixture · incident state, now 15:22
# stderr lines (counting the prompt line as 1): none
bw-pi-01 $ mainskeeper status
MainsKeeper · bw-pi-01 · site Broadwater               Wed 30 Sep 2026 15:22 PDT
■ BW Rack UPS on battery since 15:09:00 PDT · observed 13 min (live)

COLLECTOR
  bw-pi-01
  Raspberry Pi 4
  Raspberry Pi OS 12
  site witness (always-on)
SERVICE
  ● running
  mainskeeperd 0.4.2 (systemd)
  since Mon 14 Sep 03:12 PDT
CLOUD
  ● connected
  Heartbeat on time · last contact 4 s ago · every 15 s
  heartbeat 15 s (local override)
ROLES
  UPS monitoring on
  connectivity monitoring on
  applied (set in the dashboard)

UPS
  2 UPSs on this collector
  BW Rack UPS
    Power         ■ on battery
    Charge        71%
    UPS estimate  18 min est.
    Load          38%
    Reading       On schedule · 4 s · every 30 s

  BW Office UPS
    Power         ● on utility
    Charge        100%
    UPS estimate  ▨ Unsupported
    Load          12%
    Reading       On schedule · 7 min · every 10 min
  freshness     every 30 s: On schedule ≤ 60 s · Overdue ≤ 90 s · Stale · last
                known beyond (allowance 30 s)
                every 10 min: On schedule ≤ 15 min · Overdue ≤ 25 min · Stale ·
                last known beyond (allowance 5 min)

BW Rack UPS
  APC Smart-UPS SMT1500
  USB
  circuit A (rack)
  reading       On schedule · read 4 s ago · expected every 30 s · at 15:21:56
  on battery    observed 13 min since 15:09:00 PDT (measured, live)
  input · temp  0 V · 31 °C
  UPS estimate  18 min est. · initial estimate 34 min at 15:09
  powers        bw-router, bw-nas-01, bw-switch-24 (configured)
BW Office UPS
  Eaton 5S 700
  SNMP v3 card 10.0.20.15
  circuit B (office, separate)
  reading       On schedule · read 7 min ago · expected every 10 min · at
                15:15:00 · next report due by 15:25:00
  input · temp  121 V · ▨ Unsupported
  secret        Configured · last test 15:20:10 (stored locally)
  powers        bw-desk-ws — sleeping, no agent (relationship recorded)

CONNECTIVITY
  ● 3 of 3 targets answering
  gateway 192.168.10.1
  checked 20 s ago

INCIDENT
  ■ INC-0412 BW Rack UPS on battery
  Critical
  Open
  Not acknowledged
  First evidence        15:09:00 PDT · UPS reported on battery (received
                        15:09:01)
  Grace period started  15:09:00 PDT · 60 s on-battery delay
  Declared              15:10:00 PDT · still on battery after 60 s
  Acknowledged          Not acknowledged
  notified              email delivered 15:10:04 · push delivered 15:10:05
  low runtime           rule “UPS estimate < 10 min” not triggered

HISTORY SYNC
  ● current
  0 pending
  12.4 MB of 2 GB disk cap

DASHBOARD
  https://mainskeeper.example.net/incidents/INC-0412
  site          1 of 2 UPSs on battery · 1 on utility (separate circuit)
  fleet         2 open incidents (1 critical, 1 warning; 0 acknowledged)
  collectors    4 of 6 expected collectors reporting · 1 workstation asleep
  › Acknowledge in the dashboard. The CLI changes nothing on the UPS or
    equipment.

Battery Assurance
  Read-only. Never starts self-tests or transfers.
  BW Rack UPS   Battery operation observed: 13m so far at ~38% load (live)
  BW Office UPS Evidence overdue under 60-day policy · self-test PASS (date
                unknown)